Right atrial pressure assessment: IVC and hepatic vein flow

Review IVC and hepatic-flow inputs in EchoSuite’s right atrial pressure tool, with acquisition guidance and supporting reference context.

Created by Mohammed Kamareddine, MD · Sources & educational scope

Open interactive calculator →

Method

RAP category from IVC diameter and inspiratory collapse

Use the measurement units shown below. Some fields apply only to a selected method or condition; follow the interactive tool’s method choices. The interactive tool keeps missing measurements incomplete and provides its method-specific results and reference context.

Measurements and acquisition

Measurement

Enter the measured value in the displayed unit

  • IVC estimate
  • Measured collapse
  • Hepatic S / D
  • Confirm the variable matches the selected formula.
  • Use the unit displayed beside the field.
  • Keep measurements from the same representative hemodynamic state.

IVC diameter cm

Subcostal long axis · M-mode or 2D

  • From subcostal IVC long axis, measure end-expiratory diameter 0.5–3.0 cm proximal to the right-atrial ostium.
  • Keep the calipers perpendicular to the IVC and observe variation with both a sniff and quiet respiration.
  • Record whether inspiratory collapse is at least 50%; do not use collapse alone during positive-pressure ventilation.

Collapse with sniff

Subcostal long axis · M-mode or 2D

  • At least 50%
  • Less than 50%
  • From subcostal IVC long axis, measure end-expiratory diameter 0.5–3.0 cm proximal to the right-atrial ostium.
  • Keep the calipers perpendicular to the IVC and observe variation with both a sniff and quiet respiration.
  • Record whether inspiratory collapse is at least 50%; do not use collapse alone during positive-pressure ventilation.

End-expiratory maximum cm

Enter the measured value in the displayed unit

  • Confirm the variable matches the selected formula.
  • Use the unit displayed beside the field.
  • Keep measurements from the same representative hemodynamic state.

Sniff minimum cm

Enter the measured value in the displayed unit

  • Confirm the variable matches the selected formula.
  • Use the unit displayed beside the field.
  • Keep measurements from the same representative hemodynamic state.

Same site and plane

Enter the measured value in the displayed unit

  • Both walls tracked
  • Out-of-plane / uncertain
  • Confirm the variable matches the selected formula.
  • Use the unit displayed beside the field.
  • Keep measurements from the same representative hemodynamic state.

Peak forward S cm/s

Enter the measured value in the displayed unit

  • Confirm the variable matches the selected formula.
  • Use the unit displayed beside the field.
  • Keep measurements from the same representative hemodynamic state.

Peak forward D cm/s

Enter the measured value in the displayed unit

  • Confirm the variable matches the selected formula.
  • Use the unit displayed beside the field.
  • Keep measurements from the same representative hemodynamic state.

Usable forward peaks

Enter the measured value in the displayed unit

  • Yes
  • Systolic reversal
  • Uncertain / limited
  • Confirm the variable matches the selected formula.
  • Use the unit displayed beside the field.
  • Keep measurements from the same representative hemodynamic state.

Ventilation

Subcostal long axis · M-mode or 2D

  • Spontaneous breathing
  • Positive-pressure ventilation
  • From subcostal IVC long axis, measure end-expiratory diameter 0.5–3.0 cm proximal to the right-atrial ostium.
  • Keep the calipers perpendicular to the IVC and observe variation with both a sniff and quiet respiration.
  • Record whether inspiratory collapse is at least 50%; do not use collapse alone during positive-pressure ventilation.

Secondary evidence when discordant

Subcostal long axis · M-mode or 2D

  • None present
  • One or more present
  • Unavailable / uncertain
  • From subcostal IVC long axis, measure end-expiratory diameter 0.5–3.0 cm proximal to the right-atrial ostium.
  • Keep the calipers perpendicular to the IVC and observe variation with both a sniff and quiet respiration.
  • Record whether inspiratory collapse is at least 50%; do not use collapse alone during positive-pressure ventilation.

Marked venous signs with IVC >2.5 cm

Subcostal long axis · M-mode or 2D

  • No
  • Yes
  • From subcostal IVC long axis, measure end-expiratory diameter 0.5–3.0 cm proximal to the right-atrial ostium.
  • Keep the calipers perpendicular to the IVC and observe variation with both a sniff and quiet respiration.
  • Record whether inspiratory collapse is at least 50%; do not use collapse alone during positive-pressure ventilation.

Sources and method context

American Society of Echocardiography · 2025 · Guidelines for the Echocardiographic Assessment of the Right Heart in Adults and Special Considerations in Pulmonary Hypertension · RAP section and Figure 3 · PDF pp. 19–20 and 23

Primary reference

Catalogue review status: Exact guideline locator mapped · clinical sign-off pending

These pages describe the educational tool. Interpret measurements with the complete clinical context and the method’s acquisition limitations.

Keep exploring

All echo guides · Learning paths

About EchoSuite

Explore echocardiography.

Mohammed Kamareddine, MD

Explore EchoSuite

Sources & licences

Original EchoSuite teaching overlays and software © Mohammed Kamareddine, MD. Source anatomy and clinical media retain their listed rights and licences.

Acquisition guidance retains the app’s source wording: Mitchell C, Rahko PS, Blauwet LA, et al. Guidelines for Performing a Comprehensive Transthoracic Echocardiographic Examination in Adults. J Am Soc Echocardiogr. 2019;32(1):1–64. Primary reference.

Michroma by Vernon Adams · Font licence. Three.js · MIT licence.

EchoSuite is an educational product, not a diagnostic medical device.