Tricuspid regurgitation calculator: PISA quantification

Find the measurements, acquisition guidance and sources behind EchoSuite’s tricuspid regurgitation quantification tool.

Created by Mohammed Kamareddine, MD · Sources & educational scope

Open interactive calculator →

Method

EROA = 2πr²Vₐ ÷ Vmax; RVol = EROA × VTI

Use the measurement units shown below. Some fields apply only to a selected method or condition; follow the interactive tool’s method choices. The interactive tool keeps missing measurements incomplete and provides its method-specific results and reference context.

Measurements and acquisition

Measurement

Enter the measured value in the displayed unit

  • PISA
  • Vena contracta
  • Confirm the variable matches the selected formula.
  • Use the unit displayed beside the field.
  • Keep measurements from the same representative hemodynamic state.

PISA radius cm

Color Doppler · peak-flow frame

  • Zoom on the valve and center the flow-convergence region.
  • Shift the color baseline until the shell is as hemispheric as possible.
  • Measure from the regurgitant orifice to the first aliasing boundary along the jet centerline.

Aliasing velocity cm/s

Shifted color scale · absolute cm/s

  • Use the same color-Doppler frame used for the radius.
  • Read the Nyquist limit after baseline shift, not the jet velocity.
  • Enter the absolute displayed value in cm/s.

TR Vmax m/s

Continuous-wave Doppler

  • Align the CW cursor as parallel as possible to the jet.
  • Acquire a dense, complete envelope without truncation.
  • Measure the highest absolute velocity on the selected envelope.

TR VTI cm

Continuous-wave Doppler trace

  • Use the same aligned CW recording as the peak velocity.
  • Trace the outer edge of the dense envelope for the relevant phase.
  • Use the machine-reported VTI in centimeters.

Vena-contracta width cm

Enter the measured value in the displayed unit

  • Confirm the variable matches the selected formula.
  • Use the unit displayed beside the field.
  • Keep measurements from the same representative hemodynamic state.

Single jet, neck well resolved

Enter the measured value in the displayed unit

  • Yes
  • Limited / multiple jets
  • Not assessed
  • Confirm the variable matches the selected formula.
  • Use the unit displayed beside the field.
  • Keep measurements from the same representative hemodynamic state.

Sources and method context

American Society of Echocardiography · 2017 · Recommendations for Noninvasive Evaluation of Native Valvular Regurgitation · TR Table 13 pp. 46–47 · Table 14 p. 48 · Figures 30–31 pp. 49–50 · TR quantitation pp. 48–51

Primary reference

Catalogue review status: Exact guideline locator mapped · clinical sign-off pending

These pages describe the educational tool. Interpret measurements with the complete clinical context and the method’s acquisition limitations.

Keep exploring

All echo guides · Learning paths

About EchoSuite

Explore echocardiography.

Mohammed Kamareddine, MD

Explore EchoSuite

Sources & licences

Original EchoSuite teaching overlays and software © Mohammed Kamareddine, MD. Source anatomy and clinical media retain their listed rights and licences.

Acquisition guidance retains the app’s source wording: Mitchell C, Rahko PS, Blauwet LA, et al. Guidelines for Performing a Comprehensive Transthoracic Echocardiographic Examination in Adults. J Am Soc Echocardiogr. 2019;32(1):1–64. Primary reference.

Michroma by Vernon Adams · Font licence. Three.js · MIT licence.

EchoSuite is an educational product, not a diagnostic medical device.